Air Compressors UK Contact United Air Power Ltd. Service & Maintenance of Air Compressors & Compressed Air Systems Air Treatment Systems UK Air Compressor Sales & Installation United Air Power Ltd - Home Energy Efficient Compressed Air Systems & Management Compressed Air Management, Montioring & Measurement United Air Power Ltd
 
 HPC AIR TOWERS COMPARISON CHART

Model AIRTOWER 3 AIRTOWER 6
Model: AIRTOWER 3  AIRTOWER 6  airtower 6 value fo field 1  AirTower 19  AirTower 26  PAS 3S 
Performance : 0.313m3/min (11.05cfm) @7.5bar
0.233m3/min (8.23cfm) @10bar 
0.583m3/min (20.59cfm) @7.5bar
0.466m3/min (16.45cfm) @10bar
0.360m3/min (12.71cfm) @13bar 
airtower 6 value fo field 2  1.855m3/min (65.5cfm) @7.5bar
1.590m3/min (56.2cfm) @10bar
1.219m3/min (43.0cfm) @13bar 
2.544m3/min (89.8cfm) @7.5bar
2.205m3/min (77.9cfm) @10bar
1.781m3/min (62.9cfm) @13bar 
0.31m³/min (10.9cfm) @ 7.5 bar 
Package Components : Modular Compressor & Dryer  airtower 6 value fo field 3  Modular SM Compressor & TU Refrigerant Dryer  Compressor, Dryer, Sigma Control Basic, Receiver  Compressor, Dryer, Sigma Control Basic, Receiver  SX3RM + TA5 Secotec dryer 
Package Filters: Suggested Pre and After: AO/AA-0015C  Suggested Pre and After: AO/AA-0015C    AO/AA-0058G  Suggested Pre and After: AO/AA-0058G  AO/AA-0030G 
Motor Size : 2.2kW  4kW    11kW  15 kW  2.2kw 
Electrical Supply : Motor: Single Phase 230V/50Hz    Motor: Three Phase 400V/50Hz  Motor:3 Phase 400V/50Hz  Motor:3 Phase 400V/50Hz  230v/1ph/50Hz 
Dryer Power Consumption 0.34 kW  0.34kW    0.66kW  0.66  0.25kW 
Dryer Electrical Supply : Dryer: Single Phase 230V/50Hz  Dryer: Single Phase 230V/50Hz    Dryer: Single phase 230V/50Htz  Dryer: Single Phase 230V/50Hz  230v/1ph/50Hz 
Noise Level* : 65dB(A)  66dB(A)    67dB(A)  67dB(A)  65dBA 
Air Outlet Connection : G 3/4    G3/4  G1  G1  ¾" BSP 
Overall Length : 638mm  638mm    788mm  788mm  1800mm 
Overall Width : 669mm  669mm    820mm  820mm  800mm 
Overall Height : 1284mm    1284mm  1500mm  1500mm  1537mm 
Net Weight : 165kg  205kg    315Kg  335kg  412kg 
Recommended Receiver : 250ltr  250ltr    250ltr/15bar  250ltr/15bar  170 liters 
*In accordance with ISO1217 Part1 annex C
Metric conversion for m³/min to ft³/min (cfm) - multiply by a factor of 35.315
**Noise level read at 1 metre in open field conditions in accordance with PN8NTC2.3

 
 
Home  |  Hire/Rentals  |  Used Products  |  News  |  Links  |  Add to Favorites  |  Contact Us